ID24 'Configuration list MDT'

Sphere of action:

GLOBAL

Default value:

-

Access:

READING / WRITING

Scale:

1

Temporarily changeable:

NO

Unit:

-

Data length:

2 byte / element

Min. value:

-

Signed:

NO

Max. value:

-

Format:

DEC

Current list length:*

-

List:

YES

Maximum list length:*

Device-specific values

*

The list length is the number of usage data elements without 4 byte head elements.

Values for KW-R24-R / 

Maximum list length:

40

 

The 'Configuration list MDT' defines what parameters are cyclically transferred into the master data telegram (MDT) if 'Telegram types parameter' 'configured telegram' is selected in ID15. The configurable parameters are listed in ID188.

Configuration ID24 'Configuration list MDT'

List element

Content

Meaning

0

x

List head: Current list length without list head [x byte]

(x = n elements x 2 byte / element)

1

2 x z

List head: Maximum list length without list head [byte]

2

 

1st parameter

3

  2nd parameter

4

  3rd parameter

...

... ...

z+1

 

zthe parameter

z