ID24 'Configuration list MDT'
Sphere of action: |
GLOBAL |
Default value: |
- |
Access: |
READING / WRITING |
Scale: |
1 |
Temporarily changeable: |
NO |
Unit: |
- |
Data length: |
2 byte / element |
Min. value: |
- |
Signed: |
NO |
Max. value: |
- |
Format: |
DEC |
Current list length:* |
- |
List: |
YES |
Maximum list length:* |
Device-specific values |
* |
The list length is the number of usage data elements without 4 byte head elements. |
Values for
Maximum list length: |
40 |
The 'Configuration list MDT' defines what parameters are cyclically transferred into the master data telegram (MDT) if 'Telegram types parameter' 'configured telegram' is selected in ID15. The configurable parameters are listed in ID188.
List element |
Content |
Meaning |
---|---|---|
0 |
x |
List head: Current list length without list head [x byte] (x = n elements x 2 byte / element) |
1 |
2 x z |
List head: Maximum list length without list head [byte] |
2 |
1st parameter |
|
3 |
2nd parameter | |
4 |
3rd parameter | |
... |
... | ... |
z+1 |
zthe parameter |
z |
= Maximum list length |