ID111 'Motor nominal current IN'

Sphere of action:

DRIVE

Default value:

2500

Access:

READING / WRITING

Scale:

0.001

Temporarily changeable:

NO

Unit:

A

Data length:

4 byte

Min. value:

0.000 A

Signed:

NO

Max. value:

1000.000 A

Format:

DEC

   

List:

NO

   

 

The 'Motor nominal current IN' is used as a reference size for all torque data and may amount to a maximum of 80 % of the ID110 'Converter peak current' (ID111ID110 × 80 %). Der 'Motor nominal current IN' is on the motor type plate and in the motor data sheet.