0x22C2 'V/F integrator stop'

Supported hardware:

KW-R24 /  KW-R24-R /  KW-R25 /  KW-R26 /  KW-R27 /  iX(-R3) / iC(-R3) / iDT5(-R3) /  ihXT / 

Object description

Index

0x22C2

Name

'V/F integrator stop'

Object type

VAR

Data type

UNSIGNED16

 

The 'V/F integrator stop' works with the function U/f operation (0x2253=0x20) and specifies a variable percentage value of the maximum current converter. If the adjustable percentage value of the maximum current converter is achieved, the speed curve is limited internally in the device, which will not be shut down with an error message (0x2110 'Short circuit/earth leakage' or 0xFF03 'IGBT over current'). The acceleration and deceleration times are extended by the internal limiting.

 

0x22C2 = 0

no internal limiting

0x22C2 = 100

Limiting from 100% 0x206E 'Inverter peak current'

Entry description

Access

read/write

PDO mapping

no

Range of values

UNSIGNED16

Scaling

1

Unit

%

Default value

0

Min. value

0

Max. value

100