ID95 'Diagnosis [ASCII text]'

Sphere of action:

GLOBAL / FORMAL

Default value:

-

Access:

READING

Scale:

1

Temporarily changeable:

NO

Unit:

-

Data length:

1 byte (element)

Min. value:

-

Signed:

NO

Max. value:

-

Format:

ASCII

Current list length:*

-

List:

YES

Max. list length:*

Device-specific values

*

The list length is the number of usage data elements without 4 byte head elements.

Values for KW-R07 /

Max. list length:

1280

 

In the 'Diagnosis [ASCII text]', the drive's current relevant operating mode is displayed as a diagnostic number and plain text. The completion of the plain text message is marked with the symbol '\0'.

Configuration ID95 'Diagnosis [ASCII text]' example for the error message 2320 EF inactive

List element

Content

Meaning

0

x

List head: Current list length without list head [byte] (x = n elements x 1 byte / element)

1

z

List head: Maximum list length without list head [byte]

2

e.g. 2

Diagnostic number (MSB)

3

e.g. 3

Diagnostic number

4

e.g. 2

Diagnostic number

5

e.g. 0

Diagnostic number (LSB)

6

e.g. 0

Reserved

7

e.g. 0

Reserved

8

e.g. E

Plain text

9

e.g. F Plain text

10

  Plain text

11

e.g. I Plain text

12

e.g. N Plain text

13

e.g. A Plain text

14

e.g. K Plain text

15

e.g. T Plain text

16

e.g. I Plain text

17

e.g. V Plain text
... ... ...

n

\0

End of the plain text message