Binary inputs and binary outputs

Binary inputs

X121: 8 standard binary inputs E1 ... E8

 

X122: 2 probe inputs

 

Binary outputs

X122: 6 standard binary outputs A1 ... A6

 

The binary outputs A1 + A2 can be alternative use as time stamp outputs. The time stamp outputs will be activated with CANopen object 0x6300 Sub 2.

The status of the binary outputs will be set with the AMK function block 'SET_TS_OUTPUTS'

 

AMK service information:

Control word

Index

Subindex

Value -

Mode output

Meaning

0x6300

2

3h (default)

6 standard binary outputs

0x6300

2

0h

2 timestamp outputs (X122 conection 4/5)

4 standard binary outputs

Changes in parameter setting will become active after execute a system booting!

 

Access to the binary output word (default)

Binary output

Index

Subindex

PLC access

Parameter

Standard

0x6300

1

I/O image of the CODESYS plc configuration

ID34120 'Binary output word'

 

Output word Index 0x6300 Sub 1 when output mode Index 0x6300 Sub 2 = 0x3

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

-

-

-

-

-

-

-

-

-

-

A6

A5

A4

A3

A2

A1

X122, connection

-

-

-

-

-

-

-

-

-

-

9

8

7

6

5

4

 

Output word Index 0x6300 Sub 1 when output mode Index 0x6300 Sub 2 = 0x0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

-

-

-

-

-

-

-

-

-

-

A6

A5

A4

A3

-

-

X122, connection

-

-

-

-

-

-

-

-

-

-

9

8

7

6

5

4