Main contactor
To supply power to the compact power supply, a main contactor with force-driven contact has to be installed. The contactor coil requires an EMI suppressor. The control voltage for the contactor coil has to be provided externally. The switch status of the main contactor can be monitoring using the auxiliary contact HK (NC). The activation time of the main contactor must be < 150 ms; if not, the compact power supply generates a diagnostic message.
Selection main contactor
Contactor EMI suppressor |
KEN 5-0N |
KE 10 |
KEN 20-0N |
KE 20-F |
KES 20 |
---|---|---|---|---|---|
Contactor | |||||
Typ |
main contactor |
25A 3P |
main contactor |
45A 3P |
|
AMK part number |
- |
204297 |
- |
204298 |
|
EMI suppressor |
|||||
AMK part number |
not necessary |
not necessary |
not necessary |
not necessary |
|
Auxiliary contact |
|||||
AMK part number |
not necessary |
not necessary |
not necessary |
204300 |
Contactor EMI suppressor |
KE 40 KE 40-0EU |
KES 40-0EU |
KEN 60(KE 60-S4) |
KES 60 |
KEN 120 |
---|---|---|---|---|---|
Contactor | |||||
Typ |
80A 3P |
90A 3 P |
230A 3P |
||
AMK part number |
29297 |
29298 |
200446 |
||
EMI suppressor |
|||||
AMK part number |
29300 |
29300 |
not necessary |
||
Auxiliary contact |
|||||
AMK part number |
not necessary |
not necessary |
not necessary |
Contactor EMI suppressor |
KES 120 |
KE 180-0EU |
KES 180-0EU |
---|---|---|---|
Contactor | |||
Typ |
230A 3P |
350 A |
|
AMK part number |
200446 |
204558 |
|
EMI suppressor |
|||
AMK part number |
not necessary |
not necessary |
|
Auxiliary contact |
|||
AMK part number |
not necessary |
not necessary |
Further Information: see device description Main contactor (AMK part no. 203422)
The main contactor can also be supplied by the customer.
The configuration is then based on the rated voltage of the network (400V...480V AC, 50/60Hz) and the rated input current of the KE module in use.