[X18] power output stage enable transmission

NOTICE

Material Damage!

Material damage caused by incorrect handling!

Mechanical damage to terminals!

Disconnected signal lines.

Steps to prevent:

  • The plug connectors are partially encoded. Do not push in with force.
  • Never pull on the cable, but rather on the connector casing.
  • For service purposes, use the control tap.

 

Description: 

Siehe 'Function description - EF safety function'.

Technical data:

Version:

Type

Pins

Connector with spring connection

4

Assignment of X18 axis A:

[X18A]

Connection

Signal

Description

front view, device side

1

QESA

Acknowledgement power output stage blocked; the motor is not energised.

Prerequisite EF = 0 AND EF2 = 0

Relay contact NC (24 VDC, max. 200 mA).

2

QEF

Acknowledgement of power output stage enable

Prerequisite EF = 1 AND EF2 = 1

3

EF2

Power otput stage enable EF2

Signal identical to X17 Pin 1; for forwarding to further KW modules

4

EF

Power output stage enable EF

Signal identical to X17 Pin 3; for forwarding to further KW modules

Assignment of X18 axis B:

[X18B]

Connection

Signal

Description

front view, device side

1

WQSB

Feed +24 V ext. for relay contact QESB

2

QEF

Acknowledgement of power output stage enable

Prerequisite EF = 1 AND EF2 = 1

3

EF2

Power otput stage enable EF2

Signal identical to X17 Pin 1; for forwarding to further KW modules

4

EF

Power output stage enable EF

Signal identical to X17 Pin 3; for forwarding to further KW modules

Connection:

Recommended
cable type

4-wire, unshielded

Further information: Siehe 'Wiring'.

Cable assembly

Flexible line or wire end ferrule without plastic sheath

Shield connection

-

 

KWDs with EF logic

Cross-section

min./max.

0.25 mm² / 0.5 mm²

AWG 24 / AWG 20

Recommended
wire cross-sections

0.5 mm2

AWG 20

Cable stripping length

8 mm

Terminal

FK-MC 0,5/4-ST-2,5