[X21] two binary outputs and supply voltage for X21 and X22
NOTICE |
|
---|---|
Material Damage! |
Material damage caused by incorrect handling! Mechanical damage to terminals! Disconnected signal lines. Steps to prevent:
|
Description:
Terminal X21 features 2 binary outputs.
The supply voltage for terminals X21 and X22 is applied on terminal X21.
Technical data:
- Potentially separated by optocoupler
- Encoding pin 2
- Nominal voltage outputs: +24 V ext
- Nominal current (outputs): 100 mA, permanently short-circuit safe
- Updates: 1 ms
Version:
Type |
Pins |
---|---|
Connector with spring connection |
4 |
Assignment:
[X21] |
Connection |
Signal |
Description |
---|---|---|---|
front view, device side |
1 |
SBM |
Binary output 1 (BA1) Default assignment: Code 33029 (SBM) The output indicates the fault-free status of the module.
Binary output 1 can be freely configured. ID32865 'Port 3 Bit 0' |
2 |
DC Bus Enable |
Binary output 2 (BA2) Default assignment: Code 33030 (QUE) The output indicates a loaded DC bus.
Binary output 2 can be freely configured. ID32866 'Port 3 Bit 1' |
|
3 |
0 V |
Reference potential of the external supply voltage 24V DC |
|
4 |
24 VDC |
Shared feed of the external supply voltage 24 VDC for the binary outputs to X21 and X22. |
Recommended |
4-wire, shielded Further information: Siehe 'Wiring'. |
Cable assembly |
Flexible line or wire end ferrule without plastic sheath |
Shield connection |
Lay on one end on the module casing |
|
Complete KEN / KE / KES series |
---|---|
Cross-section min./max. |
0.25 mm² / 0.5 mm² AWG 24 / AWG 20 |
Recommended |
0.5 mm² AWG 20 |
Cable stripping length |
8 mm |
Terminal |
FK-MC 0,5/4-ST-2,5 |
Note |
The 0 V potential should be earthed at the central PE. |