Technical data KEN 10, KEN 10-F, KE 10

Nominal data

Terminal

KEN 10

KEN 10-F

KE 10

Input voltage

(power supply)

 

X07

 

3 x 400 VAC, 47...63 Hz

 

-

Input current

(power supply)

 

X07

 

15 A

 

-

Input voltage

(power supply)

(charging circuit)

 

X01

X20

 

-

-

 

-

-

 

3 x 400 VAC,
47...63 Hz

Input current

(power supply)

 

X01

 

-

 

-

 

15 A

Input voltage

(logic supply)

X08

X09

 

24 VDC

Input power

(logic supply)

X08

X09

 

20 W

 

22 W

 

7,5 W

Efficiency

 

approx. 99 %

Power factor λ

 

approx. 0,9

 

Output power

X02

10 kW

Max. output power

X02

20 kW for 60 s

Output voltage

(information: Siehe 'DC bus voltage'.)

X02

540 VDC

Output current

X02

19 A (at 540 VDC)

 

Regenerative feedback

 

no

Line-synchr. block feedback

Max. generative power

(regenerative feedback)

 

-

20 kW for 60 s

Braking transistor

 

Integrated

Brake threshold

 

800 VDC

Shutdown threshold of the DC bus overvoltage

 

850 VDC

Shutdown threshold of the DC bus undervoltage

 

SEEP value typically 385 VDC

parametrization with ID32837 'DC bus voltage monitoring'

External brake resistor

X03

Rev. 1.00: min. 33 Ohm
Rev. 1.01 and higher:
min. 22 Ohm

min. 20 Ohm

Protective/

monitoring functions

 

Line overcurrent (I2t),
Protection system - charging resistor,

Short circuit external braking resistor,

Excess temperature heat sink and external brake resistor

Fieldbus connection

X236

X237

 

ACC bus

 

Interference filter

(EN 61800-3, table 11)

 

 

Integrated

Charging circuit, main contactor

 

Integrated

External

 

Cooling

 

External air or liquid cold plate

Integrated

External air or liquid cold plate

Max. cold plate or ambient temperature

 

 

40 °C

Module width

 

55 mm

85 mm

Weight

 

3 kg

4.2 kg